Wind, Solar, and Battery Voltage Data
Measurement
- Volts: Data from battery voltage monitor
- Amps In: Charging current
- Solar: Charging current from the solar array (200 watt)
- Wind 1: Charging current from the #1 wind turbine
- Wind 2: Charging current from the #2 wind turbine
- Total: Sum of the solar,wind 1,wind 2 averages
- Amps Out: Battery current being used , drained for work
- Last Minute
- Data from the reception of the last data bundle from the data logger. Data
is received approximately every 1 minute. During the 1 minute the data
logger takes 30 samples from each of the monitoring devices before transmitting
the bundle.
- Average: The average of the 30 samples for each measurement. The "Total"
value in the average column is the addition of the averages from the (3)
amps in monitors
- "Max" and "Min" are the maximum and minimum values
from each sample set (the range of values)
- Today
- Data from 12 AM of the current day
- Average: Average recorded values since the start of the day, the values
averaged are the "Average" values take from each of the "Last
Readings" that has occured
- "Max" and "Min" are the maximum and minimum values
recorded for the day, up to the current point
Calculated power (Voltage x Current)
- Watts: "Out" is the Average Volts times the Average Amps Out
from the last reading, "In" is the Average Volts times the Total
Amps in from the last reading
- Today Watt Average: "Out" is the Average Volts times the Average
Amps Out for today, "In" is the Average Volts times the Total
Amps in for today